Finding an Appliance's Startup Watts in Its Manual or Label
Look at the appliance's label first, then its manual, then the maker's support page. If none of them gives a starting figure, ask the maker. A rule of thumb is a last resort, and you should say so when you use one.
What you'll need
- The appliance's model number, from its label.
- A pen and paper, or a phone to photograph the label.
- Internet access for the maker's support page, or a phone to call the maker.
Step 1: the label
Most appliances have a label or plate with the model number and the electrical ratings. It may be on the back, on a side panel, or inside a door or cabinet. Don't pull a fridge or pump apart to reach it, and don't open any electrical cover.
The label often gives volts and amps, and sometimes watts. These are usually the running figures. The starting figure often isn't there. That's normal, so move to the manual.
Step 2: the manual
Look in the specifications or electrical section. Words to watch for:
- "Starting" or "start-up" watts or amps.
- "Surge" or "inrush".
- "Locked-rotor amps" or "LRA", the current a motor draws when it's stalled.
- "Running" or "rated" watts or amps.
The locked-rotor figure matters because a stalled motor draws a large current. One source says that when a motor is first energized, "a current equivalent to the stalled current will flow"1. If the manual lists it, that figure is the closest real number to your starting need.
If the manual gives amps and not watts, convert with care. Volts times amps give volt-amperes. For motors the two can differ, because "the apparent power is greater than the real power"2.
Step 3: the maker's support page
Many makers post manuals and spec sheets online. Search for the model number from the label. Use the maker's own pages, not a shop listing. If the page is a sales page with a price and a buy button, it isn't a source for this.
Step 4: ask
Contact the maker's support team, giving the model number. Ask for the starting or locked-rotor current. For anything about connecting a backup unit to the home's wiring, ask a licensed electrician.
About rules of thumb
You'll see multipliers online. They're rough. The sump pump reference gives one figure for the extra starting burst of those pumps3. Another says the stalled current for standard Design B induction motors is typically between 6 and 7 times rated current4. These measure different things, an extra burst on top of running watts and locked-rotor current as a multiple of rated current. Check your own appliance's manual instead of relying on a multiplier.
The inrush source says "several times their normal full-load current"1. "Several times" isn't a number you can plan around. Your appliance's own paperwork is.
What to do with the figure
Write the running and starting figures next to each other for each appliance. Then compare them with your backup unit's continuous and surge ratings, as in Inverter surge ratings. Leave any wiring to a licensed electrician, and follow the manual for your own products.
Where the facts come from
- Inrush current, Wikipedia
- Volt-ampere, Wikipedia
- Sump pump, Wikipedia
- Induction motor, Wikipedia