How an Inverter's Surge Rating Relates to Motor Startup
An inverter's surge rating is the most power it can deliver for a short time. It exists for loads like motors that need a burst to start. A unit's continuous rating covers running; the surge rating covers starting.
What you'll need
- The inverter or battery unit's manual or spec sheet.
- The running and starting figures for the appliance. The two-number page explains these.
- Patience for reading the fine print, because makers word this differently.
Two ratings, two jobs
Most units list a continuous rating and a surge rating. The continuous rating is what the unit can supply as long as it has charge and stays within limits. The surge rating is higher, but only for a short time. How short is stated in the maker's manual, and it varies. Don't assume a figure from another product.
Motors are the reason this exists. At first power-up an AC motor can draw "several times their normal full-load current"1.
Watts and VA
Some backup gear gives a rating in volt-amperes (VA) as well as watts. Some devices carry both, since the reference says they have a maximum for volt-amperes and one for watts2. It adds that "The VA rating is limited by the maximum permissible current, and the watt rating by the power-handling capacity of the device"2.
So a unit can run out of current before it runs out of watts. A motor load is a case where that can matter. Check which number your manual uses for surge.
How design affects motor starting
Not every inverter handles motors the same way. A reference page says some backup systems based on rotating machinery are "better able to provide inrush current for inductive loads such as motor startup or compressor loads"3. A typical battery inverter is built differently, so don't expect the same ability.
Waveform matters too. The inverter page says "AC motors directly operated on non-sinusoidal power may produce extra heat"4. It also notes that most AC motors will run on modified sine wave units "with an efficiency reduction of about 20% owing to the harmonic content"4. Your motor's manual may say which waveform it needs.
How to compare
- Take the appliance's starting figure from its manual or label.
- Compare it with the inverter's surge rating, using the same units, watts or VA.
- Compare the appliance's running figure with the continuous rating.
- Add in anything else that might be on at the same time.
- If any number is close, pick the smaller load or ask the maker.
If the appliance gives no starting figure, ask its maker. Look first at the label and manual guide.
What the rating doesn't tell you
The surge rating doesn't say how long a battery will last. It also doesn't say that a particular motor will start. Motors vary, and the manual for your own product has the final word.
A safety note
Don't open an inverter or battery, and don't change its cells or wiring. Connecting one to a home's circuits, a switchboard or a transfer switch is work for a licensed electrician.