Air Conditioners and Backup Power: The Startup Problem

Reviewed on November 24, 2026

An air conditioner has a compressor motor and a fan motor, and both need a burst of power to start. That's the startup problem. At first power-up a motor may draw several times its normal full-load current1. So check your battery or inverter's surge rating against the air conditioner's starting figure.

Why an air conditioner is a hard loadThermostat calls for coolingCompressor and fan motors startStartup draw hits the inverterDraw eases to running level
A compressor and a fan both have to start.

What you'll need

  • The air conditioner's label and manual.
  • The ratings printed in your battery or inverter manual.
  • A licensed electrician, for any central air conditioner or hard-wired unit.

Why they start hard

Most air conditioners use a compressor driven by an electric motor. A motor like this can pull "several times their normal full-load current" at first power-up1. An air conditioner has two such motors, the compressor and a fan.

Many air conditioners use capacitors to help the motors get going. One source says round dual run capacitors are commonly used for air conditioning "to help in the starting of the compressor and the condenser fan motor"2. If a capacitor weakens, "the motor may fail to start or to run at full power"2. A repair like that belongs to a qualified technician.

Why on-off cooling repeats the problem

A common way to control cooling is on-off cycling3. Each time the unit switches on, the motors start from rest and the burst returns. Over an afternoon, that's a lot of starts.

Types that start more gently

Some air conditioners control compressor speed instead of switching on and off. The reference describes a system that "uses a variable-frequency drive (also called an Inverter) to control the speed of the compressor"3. A related page says a drive like this starts a motor at low frequency and voltage, "avoiding high inrush-current associated with direct-on-line starting"4.

The air conditioning reference also mentions "the lower start-up power of VRF's DC inverter compressors"3. VRF is a type of multi-room system. Not every unit with "inverter" in its description starts gently, so check your own manual.

Window units and central systems

A window unit usually plugs into an outlet. A central system is wired into the house and often into its own circuit. The wiring side is licensed electrician work, with no exceptions. Don't connect a central air conditioner to a battery or inverter yourself.

What to check before trying

  1. Look up the air conditioner's own running and starting numbers.
  2. Read what your battery or inverter can supply, both continuously and for a short surge.
  3. Make sure both cover the air conditioner, with room to spare for anything else running.
  4. If the manual gives no starting figure, ask the maker.

The surge rating page explains what the unit's surge number means. The manual page shows where to look for the air conditioner's figure.

If the numbers don't fit

Choose something smaller to run, such as a fan, or ask an electrician about a larger system. Don't push a unit past its ratings, and don't modify a battery or its wiring. Follow your own product's manual.